產(chǎn)品標(biāo)準(zhǔn)
本防鼠防蟻電纜按GB12706- 9《額定電壓35kv 及以下銅芯、鋁芯塑料絕緣電力電纜》、GB2951.38-86《電線電纜白蟻試驗(yàn)方法》、Q/320282DCE014-2000《防鼠 電線電纜》標(biāo)準(zhǔn)生產(chǎn)。
防鼠防蟻電纜的型號(hào) Type of cable 型號(hào) Type 額定電壓 Rated voltage 名稱 Designation
銅芯 Copper conductor 鋁芯 Aluminum conductor
FSH-VV FSH-VLV 0.6/KV 聚氯乙烯絕緣聚氯乙烯護(hù)套防鼠電力電纜 PVC insulated , PVC sheathed mouseproof power cable
FSH-VV
FSH-VY FSH-VLY
FYH-VLY 聚氯乙烯絕緣聚乙烯護(hù)套防鼠電力電纜 PVC insulated , PE sheathed mouseproof power cable 聚氯乙烯絕緣聚乙烯護(hù)套防白蟻電力電纜 PVC insulated , PE sheathed temiteproof power cable
FSH-VV22 FSH-VLV22 聚氯乙烯絕緣鋼帶鎧裝聚氯乙烯護(hù)套防鼠電力電纜 PVC insulated ,steel tape armoured, PVC sheathed mouseproof power cable
FSH-VV23 FYH-VV23 FSH-VLV23 FYH-VLV23 聚氯乙烯絕緣鋼帶鎧裝聚乙烯護(hù)套防鼠電力電纜 PVC insulated, steel tape armoured ,PE shesthed mouseproof power cable 聚氯乙烯絕緣鋼帶鎧裝聚乙烯護(hù)套防白蟻電力電纜 PVC insulated, steel tape armoured ,PE sheathed termiteproof power cable
FSH-VV32 FSH-VLV32 聚氯乙烯絕緣細(xì)鋼絲鎧裝聚氯乙烯護(hù)套防鼠電力電纜 PVC insulated, steel wire armoured ,PVC sheathed mouseproof power cable
FSH-VV33 FYH-VV33 FSH-VLV33 FYH-VLV33 聚氯乙烯絕緣細(xì)鋼絲鎧裝聚乙烯護(hù)套防鼠電力電纜 PVC insulated, steel wire armoured ,PE sheathed mouseproof power cable 聚氯乙烯絕緣細(xì)鋼絲鎧裝聚乙烯護(hù)套防白蟻電力電纜 PVC insulated, steel wire armoured ,PE sheathed termiteproof power cable
FSH-YJV FSH-YJLV 6/1KV ~ 26/35KV 交聯(lián)聚乙烯絕緣聚氯乙烯護(hù)套防鼠電力電纜 XLPE insulated, PVC sheathed mouseproof power cable
FSH-YJV FYH-YJY FSH-YJLV FYH-YJLV 交聯(lián)聚乙烯絕緣聚乙烯護(hù)套防鼠電力電纜 XLPE insulated, el wire ,PE sheathed mouseproof power cable 交聯(lián)聚乙烯絕緣聚乙烯護(hù)套防白蟻電力電纜 XLPE insulated, steel wire ,PE sheathed termiteproof power cable
FSH-YJV22 FSH-YJLV22 交聯(lián)聚乙烯絕緣鋼帶鎧裝聚氯乙烯護(hù)套防鼠電力電纜 XLPE insulated, steel tape armoured ,PE sheathed mouseproof power cable
FSH-YJV23 FYH-YJV23 FSH-YJLV23 FYH-YJLV23 交聯(lián)聚乙烯絕緣鋼帶鎧裝聚乙烯護(hù)套防鼠電力電纜 XLPE insulated, steel tape armoured ,PE sheathed mouseproof power cable 交聯(lián)聚乙烯絕緣鋼帶鎧裝聚乙烯護(hù)套防白蟻電力電纜 XLPE insulated, steel tape armoured ,PE sheathed termiteproof power cable
FSH-YJV32 FSH-YJLV32 交聯(lián)聚乙烯絕緣細(xì)鋼絲鎧裝聚氯乙烯護(hù)套防鼠電力電纜 XLPE insulated, steel wire armoured ,PVC sheathed mouseproof power cable
FSH-YJV33 FYH-YJV33 FSH-YJV33 FYH-YJLV33 交聯(lián)聚乙烯絕緣細(xì)鋼絲鎧裝聚乙烯護(hù)套防鼠電力電纜 XLPE insulated, steel wire armoured ,PE sheathed mouseproof power cable 交聯(lián)聚乙烯絕緣細(xì)鋼絲鎧裝聚乙烯護(hù)套防白蟻電力電纜 XLPE insulated, steel wire armoured ,PE sheathed termiteproof power cable
使用特性 Operating characteristics
·電纜導(dǎo)體的長(zhǎng)期高允許工作溫度:
e continuous operating temperature of the conductor.
聚氯乙烯絕緣不超過(guò)70,交聯(lián)聚乙烯絕緣不超過(guò)90。
PVC insulated:70,XPLE insulated :90
·短路時(shí)(5秒內(nèi))高溫度
-circuit temperature of the conductor (5s )
聚氯乙烯絕緣不能超過(guò)160,交聯(lián)聚乙烯絕緣不超過(guò)250。
·電纜敷設(shè)溫度不能低于0。
·The ambient temperature under installation should not below 0。
·電纜的彎曲半徑為:
·The bending radius of a cable 。
·單芯電纜不小于電纜外徑的20倍;多芯電纜不小于電纜外徑的15倍;
·single –core cables should not less than 20 times of the cable diameter , others not less than 15 times of the cable
- 打印本文
- 關(guān)閉本頁(yè)
- 瀏覽: